EC Motor and EC Fan
PANKA FanPengke PLFH External Rotor Centrifugal Fan
The PLFH series is a PANKA centrifugal fan with an external rotor motor. Its integrated motor and impeller design features a compact axial profile, minimizing installation space. The modular architecture allows flexible arrangement to suit various duct configurations. Key performance metrics include a maximum airflow of 7000 m³/h, a maximum pressure of 1000Pa, and a peak efficiency of 65%. Impeller diameters range from 190 mm to 450 mm. Available materials include galvanized steel, aluminum alloy, and composite options, selectable based on media cleanliness and corrosion resistance requirements. Typical applications include small HVAC systems, air purification units, and cleanroom FFU (Fan Filter Unit) modules. It is also ideal for internal equipment cooling, cabinet ventilation, and small-scale fresh air exchange. CE certified; AMCA performance certification available upon request.
Technical Specifications
- Max Airflow7000 m³/h
- Maximum Pressure1000 Pa
- Maximum overall efficiency65%
- Impeller Diameter190mm~450mm
- Impeller MaterialGalvanized steel, aluminum alloy, composite materials
- Structure TypeDirect-coupled outer rotor motor with modular design
- Drive TypeEC Electronic Commutation Motor / AC Motor
- Ingress Protection RatingIP4
- VerifyCE, AMCA (optional)
- Installation MethodBuilt-in, flange-mounted
Key Advantages
Integrated outer-rotor motor and impeller design with a compact axial profile
Modular design for flexible assembly and easy multi-point deployment within the unit.
Maximum system efficiency of 65%, with significant energy savings at partial load.
Impeller material options: galvanized steel, aluminum alloy, composite materials.
Compatible with small HVAC units and cleanroom FFU fan filter units
CE certified; AMCA performance certification available upon request
Use Cases
Compact HVAC unit with built-in air supply
Air Purification Unit and Cleanroom FFU
Equipment Cabinet Cooling and Ventilation
Compact Fresh Air Ventilation System
Pengke PLFH External Rotor Centrifugal Fan Selection Parameters
← Swipe left or right to view full parameters; first column is fixed
| Parameter | Numeric | Description |
|---|---|---|
| Max Airflow | 7000 m³/h | Series limit, corresponding to the maximum impeller setting |
| Maximum Pressure | 1000 Pa | Maximum static pressure (series) |
| Maximum system efficiency | 65% | Maximum total pressure efficiency |
| Maximum Static Pressure Efficiency | 60% | Sample Label Value |
| Impeller Diameter | 190mm~450mm | Series Coverage |
| Impeller Material | Galvanized steel, aluminum alloy, composite materials | Select based on medium cleanliness and corrosion resistance requirements |
| Structural Form | Direct-coupled outer rotor motor with modular design | Compact axial length enables multi-point installation within the unit. |
| Drive Type | EC Electronically Commutated Motors / AC Motors | EC model supports stepless speed regulation |
| Ingress Protection Rating | IP4 | Indoor Standard Environment |
| Verify | CE, AMCA (optional) | AMCA performance certification available upon request |
The "Impeller Diameter vs. Airflow Ranges" table lists reference intervals based on the maximum performance of the PLFH series (700 m³/h, 1000Pa), scaled proportionally for preliminary model selection. Final selection must be verified against the manufacturer's performance curve and site duct resistance calculations.
Download
Pengke PLFH External Rotor Centrifugal FanProduct Catalog (PDF) – Download for full technical specs, installation dimensions, and selection tables.
Pengke PLFH External Rotor Centrifugal FanProduct Catalog
PDF Document · Free Public Download
Similar EC motor and EC fan products

Pengke PLF Centrifugal Fan (EC/AC)
Pengke PLF Centrifugal Fan (EC/AC), direct-drive motor without volute, max airflow 120000m³/h, max pressure 4500Pa, max static efficiency 79%, max total efficiency 83%, impeller diameter 250mm–1250mm. Ideal for large industrial air handling units.

Pengke PLFE Centrifugal Exhaust Fan (EC/AC)
Pengke PLFE Exhaust Centrifugal Fan (EC/AC), certified for fire safety and explosion-proof use with easy-clean design. Max airflow: 120000m m³/h, max pressure: 4500Pa, max static efficiency: 79%, max total efficiency: 83%. Impeller diameter: 225 mm ~ 1250 mm. Ideal for kitchen exhaust and fire smoke extraction.

Pengke PLFB Centrifugal Supply and Exhaust Fan Unit (EC/AC)
PENGKE PLFB Centrifugal Supply and Exhaust Fan Unit (EC/AC) with quick-release housing design. Maximum airflow: 100000m³/h, maximum pressure: 4500Pa, peak static pressure efficiency: 79%, peak total pressure efficiency: 83%. Impeller diameter: 250mm–1250mm. Ideal for ducted supply/exhaust ventilation and server room air handling.
Related Case Studies
All Cases
Mining and Metallurgy
Wolong High-Voltage Variable Frequency Drive Case Study | Pakistan K Electric Power Supply Project | MV VFD System Tendering and Engineering Delivery
Longde Electric (Zhejiang) Power Electronics issues Authorization Letter NO.WLPEFX20260019, authorizing Pakistani agent Techno Control Pvt. Ltd. to bid for the K Electric VFDs project. The project confirms ten delivery commitments—including technical clarification, drawings, protection coordination, interfaces, HVAC dimensions, foundations, signal exchange, software backup, and O&M training—as specified in the Technical Clarification Letter.

Mining and Metallurgy
Wolong High-Voltage VFD Case Study | Kenya Industrial Project | 4000kW Fan Variable Frequency Speed Control
The Kenya MVC industrial project went online in 2014 12, utilizing 1 units of 4000kW high-voltage variable frequency drives to power large-capacity fan loads, enabling on-demand speed control for the ventilation system.
Energy Saving33%Food & Beverage
Wolong EC Fan Energy Retrofit Case | Yichang Ziquan Beverage Industry Co., Ltd. | Permanent Magnet Direct-Drive EC Fan Energy Retrofit for Workshop Air Handling Units
Yichang Ziquan Beverage Industry Co., Ltd. upgraded the air handling units in Production Lines 1 and 2 from standard impellers with belt drives and three-phase asynchronous motors to卧龙 permanent magnet rotor synchronous motor direct drive, smart variable frequency systems, and high-efficiency EC fan systems. Annual power consumption dropped from 311,256kWh to 209,088kWh, achieving an overall energy savings rate of approximately 32.8%.
Cases are automatically linked by product series and application industry, allowing you to view retrofit details and performance data for similar operating conditions.
Looking for a motor and energy-saving solution tailored to your operating conditions?
Submit request. Our technical engineer will contact you within 1 business days.