Panbu Electric

Solutions

From parameter matching to whole-line energy optimization, we provide an all-in-one retrofit solution integrating motors, drives, and controls.

Solution Categories
Industries

Current filters:Industry: Shipbuilding, total1Bundle Options (Select Multiple)

ShipbuildingSensorSolutions

Temperature, pressure, water quality measurement instruments, and industry control & monitoring solutions

Measurement and Control Solutions for the Shipbuilding Industry

Sensor · Shipbuilding Measurement & Control

Measurement and Control Solutions for the Shipbuilding Industry

Tailored for the shipbuilding and marine equipment industry, we deliver temperature, pressure, level, flow, and water quality measurement and control solutions across seven key scenarios: heating and cooling systems, engines and compressors, separators, oil and gas tanks, water and wastewater treatment, ballast water management, and ship HVAC. Our offerings ensure stable vessel system operation while meeting water quality and emission compliance requirements.

Use Cases

Suitable for bulk carriers, tankers, passenger ships, supply vessels, yachts, offshore drilling platforms, and shipyards. Includes engine room heating and cooling systems, main engine and compressor monitoring, heavy fuel oil separators, LNG spherical tanks, seawater desalination and wastewater treatment, ballast water management systems, and marine HVAC systems.

Solve pain points

Engines and compressors generate extreme heat under high load; continuous real-time monitoring of mechanical components is required to prevent damage.The temperature of the LNG storage tank medium is extremely low, requiring real-time pressure monitoring without direct contact between the transmitter and the cold medium.Seawater reverse osmosis desalination requires 60 to 80 bar. Uncontrolled pressure upstream of the membrane compromises safe operation.Ballast water is drawn from coastal waters; discharge may introduce invasive species and pose compliance risks for water quality.Ship sewage must be stored or treated on-site. Uncontrolled liquid levels can cause overflow, and water quality must be tested before and after treatment.Ship HVAC systems require continuous control of temperature, humidity, and airflow; dirty ventilation ducts can harbor pathogens.Water quality analysis requires numerous, widely dispersed measurement points. Traditional cabling is inefficient, and calibration or replacement is time-consuming.

Solution Composition

JUMO VIBROtemp Screw-in RTD: Robust, vibration-resistant temperature measurement for ship main engines, lubricating oil systems, and engine control / JUMO Pt100 Temperature Sensor: Monitors temperatures in positive displacement and dynamic compressors; alerts the control system to high or low temperature conditions / JUMO MIDAS Pressure Transmitter Series: Converts mechanical pressure signals into 4~20mA or 3~5V electrical signals using a diaphragm sensor element for compressor and pipeline pressure control / JUMO MIDAS C18 SW Pressure Transmitter: Measures feedwater pressure for seawater reverse osmosis systems and monitors liquid levels on tankers, bulk carriers, passenger ships, supply vessels, and offshore drilling platforms / JUMO dTRANS p20 Pressure Transmitter: Measures cryogenic medium pressure in LNG storage tanks; the medium is heated to approximately -40°C before entering the transmitter / JUMO digiLine Smart Bus Connection System: Enables networking of digital water quality sensors in star or tree topologies; shares signal lines for simultaneous multi-parameter, multi-point measurement / JUMO AQUIS touch Multi-Channel Measurement Devices: Designed for water analysis; supports up to 6 digital sensors directly, or up to 25 with interface and input modules. Features four independent control loops, paperless recording, and tamper protection / JUMO mTRON T Automation System: Integrates digiLine sensors to monitor level, pressure, temperature, and flow for alarms; controls valves, pumps, actuators, and motors. The user interface can be customized by application or client / pH, Conductivity, Dissolved Oxygen, Turbidity, ORP, and Residual Chlorine Sensors: Used for freshwater production, wastewater treatment, and ballast water quality monitoring / Level and Temperature Sensors: Provides comprehensive control and monitoring for ballast tanks, sewage tanks, and fuel/air gas storage tanks; supports offshore installation

4Step-by-step service process

01

On-site survey

Collect load conditions, installation dimensions, and operating data

02

Selection Match

1 matches 1 parameter; output substitution and supporting solutions

03

Implementation

Replace in batches during maintenance windows to reduce downtime.

04

Energy Saving Verification

Before and after data comparison, generate verification report

Looking for a motor and energy-saving solution tailored to your operating conditions?

Submit request. Our technical engineer will contact you within 1 business days.