Panpu IoT Controller and Data Acquisition Terminal

Automation Control Products and Systems

Panbu Electric

Panpu IoT Controller and Data Acquisition Terminal

Panpu IoT Controller is a self-developed data acquisition and communication terminal that plugs into the IoT cloud platform with zero setup. Supporting multiple communication methods and system expansion options, it collects device data and unifies disparate protocols across vendors into a single, platform-compatible format—solving integration challenges caused by protocol incompatibility. Once connected, users can monitor and manage devices from mobile or PC interfaces. Combined with the cloud platform's alert notification system, operations teams can track device status and respond to issues remotely without on-site presence—ideal for remote data collection at distributed sites, unmanned pumping stations, and environmental facilities.

Technical Specifications

  • Connection MethodPlug-and-play, ready to connect to IoT cloud platforms.
  • Communication MethodMultiple communication options available (including 4G, Ethernet, RS85)
  • Extendable CapabilitiesSupports multiple system extension methods
  • Core FeaturesDevice Data Collection and Communication Protocol Integration
  • AdminView and manage device status on mobile and PC
  • Ingress Protection RatingIP4
  • Complementary capabilitiesIntegrate with cloud platform alert push notifications

Key Advantages

Plug-and-play with minimal on-site setup.

Supports multiple communication methods and system expansion options

Integrate communication protocols for multi-vendor devices

View and manage device status on both mobile and desktop.

Optimized for distributed sites and unattended scenarios

Integrate with cloud platform alert push mechanisms

Use Cases

Data collection for distributed pump stations and storage tanks

Unattended Remote Monitoring of Environmental Facilities

Unified access for multi-vendor device protocols

Retrofitting legacy systems with IoT capabilities

Panpu IoT Controller and Data Acquisition Terminal Selection Parameter Table

← Swipe left or right to view full parameters; first column is fixed

ScaleDI/DO Point ReferenceAI/AO Point ReferenceSerial Port Count ReferenceTypical Use Cases
Mini≤8≤4 lanes1 RS485Single Device Status Collection
Small8~32 o'clock4–8 lanes1~2 RS485 portsSmall pump station, single process stage
Medium32~64 o'clock8–16 lanes2~4 RS485 portsWorkshop-level multi-device data collection
Large64 and above16 or more lanes4 or more channels, or expansion modulesWhole-line or multi-site data collection

The table provides selection references for data acquisition scale tiers, communication methods, and expansion configurations based on typical project operating conditions. Actual point counts, protocol types, and installation methods must be calculated according to the on-site equipment list.

Download

Panpu IoT Controller and Data Acquisition TerminalProduct Catalog (PDF) – Download for full technical specs, installation dimensions, and selection tables.

Panpu IoT Controller and Data Acquisition TerminalProduct Catalog

PDF Document · Free Public Download

Download PDF SampleRequest more information

Related Case Studies

All Cases
Panpu SRM Variable-Speed Drive System Case Study | Rubber & Plastic Products Factory | Energy-Saving Retrofit for Injection Molding Machine Oil Pumps with Process-Stage Speed ControlEnergy Saving28%

Rubber tires

Panpu SRM Switched Reluctance Drive System Case Study | Rubber & Plastic Products Factory | Energy-saving Retrofit of Injection Molding Workshop Oil Pumps with Process-Stage Speed Control

The 12 injection molding machines in the rubber and plastic products factory's injection workshop originally used an asynchronous motor + variable pump configuration, resulting in significant energy loss via overflow during the holding pressure and cooling stages. The project has now switched to Panpu SRM switch reluctance motor drive systems for the oil pumps, enabling speed-adjusted oil supply based on process stages.

Panpu SRM Switched Reluctance Motor Drive System Case Study | Oilfield Production Zone | Beam Pump Load Speed Control and Soft Start RetrofitEnergy Saving32%

Mining and Metallurgy

Panpu SRM Switched Reluctance Motor Drive System Case Study | Oilfield Production Zone | Beam Pump Load Speed Regulation and Soft Start Retrofit

In a certain oilfield's production zone, 37 beam pumping units equipped with asynchronous motors have operated under light loads for an extended period, resulting in frequent start-stop cycles and high inrush currents. The project replaced the entire system with Panpu SRM series switched reluctance motor drive systems, enabling speed control based on the pumping unit load curve and soft starting.

Siemens SCADA Monitoring System Integration Case: Songjiang Tianma Phase II Leachate Treatment Project – Data Exchange and Wireless Transmission Between Leachate Treatment Phases I & II

Water Treatment

Siemens SCADA Monitoring System Integration Case: Songjiang Tianma Phase II Leachate Treatment Project – Data Integration and Wireless Transmission for Leachate Treatment Phases I & II

Completed Siemens SCADA system integration design for Songjiang Tianma Phase II landfill leachate treatment project. Achieved data interoperability and wireless transmission between Phase I and Phase II facilities via DCS OPC protocol, terminal device RS85 acquisition, and PLC data processing.

Cases are automatically linked by product series and application industry, allowing you to view retrofit details and performance data for similar operating conditions.

Looking for a motor and energy-saving solution tailored to your operating conditions?

Submit request. Our technical engineer will contact you within 1 business days.