Panbu Electric
WE3 Series Low-Voltage Three-Phase Induction Motors

Industrial Standard Motor

Panbu Electric

WE3 Series Low-Voltage Three-Phase Induction Motors

The WE3 series is a low-voltage three-phase asynchronous motor from Wolong, designed for the general industrial market. It features a Totally Enclosed Fan Cooled (TEFC) construction and covers frame sizes 63 to 355, with rated power ranging from 0.12 to 315kW. Rated voltages are 220V/380V/400V/660V, and rated frequencies are 50Hz/60Hz. Designed according to IEC 60034-30 energy efficiency standards, the series offers IE3 and IE4 efficiency levels, balancing high energy efficiency with cost-effectiveness. Built with premium cold-rolled silicon steel sheets and low-loss windings, combined with high-precision bearings and optimized airflow, these motors feature low temperature rise, quiet operation, and minimal vibration, making them ideal for long-term continuous duty. Mounting configurations include B3, B5, B35, and B14, allowing direct integration with gearboxes, fans, pumps, and other equipment.

Technical Specifications

  • Housing Number63~355
  • Rated Power0.12–31 5kW
  • Rated Voltage220V/380V/400V/660V
  • Rated Frequency50Hz/60Hz
  • Jisu2/4/6/8 Extreme
  • Energy Efficiency RatingIE3, IE4
  • Ingress Protection RatingIP55 (optional IP56/IP65)
  • Insulation ClassF class, temperature rise evaluated according to B class.
  • Cooling MethodIC411 Totally Enclosed Fan-Cooled
  • Installation MethodB3, B5, B35, B14, etc.
  • Work scheduleS1 Continuous Duty
  • Ambient Temperature-15°C to +40°C, altitude ≤ 1000 m

Key Advantages

High Efficiency & Energy Saving: Optimized electromagnetic design and low-loss silicon steel achieve IE3/IE4 efficiency, significantly reducing operating costs.

Robust design: Cast iron base and integral end cover for high rigidity, rapid heat dissipation, and reliable continuous heavy-duty operation.

Low Noise & Low Vibration: Precision dynamic balancing and optimized airflow design ensure smooth, quiet operation.

Insulation Durability: Class F insulation with vacuum pressure impregnation (VPI) for enhanced moisture and dust resistance, extending service life.

Flexible installation: Multiple mounting configurations and shaft extensions for direct compatibility with various transmission equipment.

Variable Frequency Compatible: Reinforced winding insulation design enables wide-range speed control when used with a variable frequency drive.

Use Cases

Fans and Ventilation Equipment

Pumps and Water Supply & Drainage Systems

Air Compressor

Conveying Machinery and Transmission Equipment

Machine Tools and General Machinery

Universal drive for metallurgy, chemical engineering, building materials, power generation, and other industries

WE3 Series Low-Voltage Three-Phase Induction Motor Selection Parameters (Representative Models for 380V/50Hz)

← Swipe left or right to view full parameters; first column is fixed

ModelHousing SizePower (kW)JiShuSpeed (r/min)Current (A)Efficiency (%)Power FactorIngress Protection RatingEnergy Efficiency Rating
WE3-63M1-2630.18228000.52650.8IP5IE3
WE3-71M1-4710.37414001.0573.50.78IP5IE3
WE3-90S-4901.1414202.681.40.79IP5IE3
WE3-112M-41124414408.886.10.82IP5IE3
WE3-132S-41325.54144011.987.20.83IP5IE3
WE3-160M-4160114146022.689.50.84IP5IE4
WE3-180M-418018.5414653691.20.86IP5IE4
WE3-225S-4225374147569.992.70.87IP5IE4
WE3-250M-4250554148010293.50.87IP5IE4
WE3-280S-4280754148513894.20.88IP5IE4
WE3-315S-431511041487201950.88IP5IE4
WE3-355M-43552504149044795.80.89IP5IE4
WE3-355L-6355315699057895.60.86IP5IE4

Download

WE3 Series Low-Voltage Three-Phase Induction MotorsProduct Catalog (PDF) – Download for full technical specs, installation dimensions, and selection tables.

WE3 Series Low-Voltage Three-Phase Induction MotorsProduct Catalog

PDF Document · Free Public Download

Download PDF SampleRequest more information

Related Case Studies

All Cases
Panpu SRM Switched Reluctance Motor Drive System Case Study | Oilfield Production Zone | Beam Pump Load Speed Control and Soft Start RetrofitEnergy Saving32%

Mining and Metallurgy

Panpu SRM Switched Reluctance Motor Drive System Case Study | Oilfield Production Zone | Beam Pump Load Speed Regulation and Soft Start Retrofit

In a certain oilfield's production zone, 37 beam pumping units equipped with asynchronous motors have operated under light loads for an extended period, resulting in frequent start-stop cycles and high inrush currents. The project replaced the entire system with Panpu SRM series switched reluctance motor drive systems, enabling speed control based on the pumping unit load curve and soft starting.

Panpu SRM Variable-Speed Drive System Case Study | Rubber & Plastic Products Factory | Energy-Saving Retrofit for Injection Molding Machine Oil Pumps with Process-Stage Speed ControlEnergy Saving28%

Rubber tires

Panpu SRM Switched Reluctance Drive System Case Study | Rubber & Plastic Products Factory | Energy-saving Retrofit of Injection Molding Workshop Oil Pumps with Process-Stage Speed Control

The 12 injection molding machines in the rubber and plastic products factory's injection workshop originally used an asynchronous motor + variable pump configuration, resulting in significant energy loss via overflow during the holding pressure and cooling stages. The project has now switched to Panpu SRM switch reluctance motor drive systems for the oil pumps, enabling speed-adjusted oil supply based on process stages.

Wolong EC Fan Energy Efficiency Retrofit Case | Yichang Ziquan Beverage Industry Co., Ltd. | Permanent Magnet Direct-Drive EC Fan Retrofit for Workshop Air Handling UnitsEnergy Saving33%

Food & Beverage

Wolong EC Fan Energy Retrofit Case | Yichang Ziquan Beverage Industry Co., Ltd. | Permanent Magnet Direct-Drive EC Fan Energy Retrofit for Workshop Air Handling Units

Yichang Ziquan Beverage Industry Co., Ltd. upgraded the air handling units in Production Lines 1 and 2 from standard impellers with belt drives and three-phase asynchronous motors to卧龙 permanent magnet rotor synchronous motor direct drive, smart variable frequency systems, and high-efficiency EC fan systems. Annual power consumption dropped from 311,256kWh to 209,088kWh, achieving an overall energy savings rate of approximately 32.8%.

Cases are automatically linked by product series and application industry, allowing you to view retrofit details and performance data for similar operating conditions.

Looking for a motor and energy-saving solution tailored to your operating conditions?

Submit request. Our technical engineer will contact you within 1 business days.